• English
  • Deutsch
  • Log In
    Password Login
    or
  • Research Outputs
  • Projects
  • Researchers
  • Institutes
  • Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Artikel
  4. Emission of perfluoroalkyl carboxylic acids (PFCA) from heated surfaces made of polytetrafluoroethylene (PTFE) applied in food contact materials and consumer products
 
  • Details
  • Full
Options
2015
Journal Article
Titel

Emission of perfluoroalkyl carboxylic acids (PFCA) from heated surfaces made of polytetrafluoroethylene (PTFE) applied in food contact materials and consumer products

Abstract
Polytetrafluoroethylene (PTFE) has been widely discussed as a source of perfluorooctanoic acid (PFOA), which has been used in the production of fluoropolymers. PTFE may also contain unintended perfluoroalkyl carboxylic acids (PFCAs) caused by thermolysis of PTFE, which has been observed at temperatures above 300 °C. Common PTFE coated food contact materials and consumer goods are operated at temperatures above 200 °C. However, knowledge on possible emissions of PFCAs is limited. Therefore, it was the aim of this study to investigate and evaluate the emission of PFCAs from PTFE coated products with both, normal use and overheating scenarios. Four pans, claimed to be PFOA free, and nine consumer products were investigated. At normal use conditions (<230 °C), emissions from PTFE surfaces were trapped for 1 h. Overheating scenarios (>260 °C) recorded emissions during a 30 min heating of empty pans on a stove. Emissions were analyzed by LC-ESI-MS. Results indicate the emission of PFCAs, whereas no perfluorinated sulfonic acids were traced. At normal use conditions total emissions of PFCAs accounted for 4.75 ng per hour. Overheated pans, however, released far higher amounts with up to 12 190 ng PFCAs per hour at 370 °C. Dominating contributors where PFBA and PFOA at normal use and PFBA and PFPeA during overheating. Temperature seems to be the main factor controlling the emission of PFCAs. A worst case estimation of human exposure revealed that emissions of PFCAs from heated PTFE surfaces would be far below the TDI of 1500 ng PFOA per kg body weight.
Author(s)
Schlummer, Martin
Fraunhofer-Institut für Verfahrenstechnik und Verpackung IVV
Sölch, Christina
Fraunhofer-Institut für Verfahrenstechnik und Verpackung IVV
Meisel, Theresa
Still, Mona
Fraunhofer-Institut für Verfahrenstechnik und Verpackung IVV
Gruber, Ludwig
Fraunhofer-Institut für Verfahrenstechnik und Verpackung IVV
Wolz, Gerd
Fraunhofer-Institut für Verfahrenstechnik und Verpackung IVV
Zeitschrift
Chemosphere
Thumbnail Image
DOI
10.1016/j.chemosphere.2014.11.036
Language
English
google-scholar
Fraunhofer-Institut für Verfahrenstechnik und Verpackung IVV
  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Send Feedback
© 2022