Objectives:
The study aims on evaluation criteria applicable for the development process of new mobile 3D X-ray imaging devices, based on existent knowledge from literature and user expertise.
Methods:
For this purpose, a structured literature review was performed to outline limitations and opportunities of established systems on the market. Additionally, medical professionals from various medical fields were interviewed, following a structured interview protocol, to identify critical evaluation aspects from a user perspective.
Results:
The study identified a total of 52 evaluation criteria, which were categorized into the following domains: clinical application and manageability, image quality, radiation dose and risk of infection. The analysis of user needs, subsequent summarization, and rating of these needs will serve as a new benchmark for the evaluation of both existing and new devices. This will provide guidance to procurement, medical experts, and manufacturers.
Conclusions:
While the structured evaluation of mobile X-ray devices is possible, consultation of the users regarding their weighting of varying needs will remain an important aspect of the process. The evaluation items can serve as a starting point for this analysis.
Author(s)
Barth, Tobias
Fraunhofer-Einrichtung für Individualisierte und Zellbasierte Medizintechnik IMTE  
Bretin, Annette
Behrends, Lina Maria
Fraunhofer-Einrichtung für Individualisierte und Zellbasierte Medizintechnik IMTE  
Münch, Matthias
Fraunhofer-Einrichtung für Individualisierte und Zellbasierte Medizintechnik IMTE  
Wendlandt, Robert
Schulz, Arndt-Peter  
Fraunhofer-Einrichtung für Individualisierte und Zellbasierte Medizintechnik IMTE  
Journal
Biomedizinische Technik  
Open Access
File(s)
Download (596.35 KB)
Rights
CC BY 4.0: Creative Commons Attribution
DOI
10.1515/bmt-2025-0086
10.24406/publica-5797
Additional link
Full text
Language
English
Fraunhofer-Einrichtung für Individualisierte und Zellbasierte Medizintechnik IMTE  
Keyword(s)
  • c-arm

  • evaluation guide

  • mobile radiography

  • mobile x-ray

  • radiographer perspectives

  • quality control

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024