• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Scopus
  4. Accuracy of cross-sectional area determining methods for tensile testing of iliotibial band
 
  • Details
  • Full
Options
2026
Journal Article
Title

Accuracy of cross-sectional area determining methods for tensile testing of iliotibial band

Abstract
Determining accurate values on specimen cross-sectional areas is crucial when conducting biomechanical experiments in an effort to derive meaningful properties such as ultimate tensile strength and elastic modulus. Several studies have investigated various methods for cross-section measurements using various soft tissues and applications. Comparison between methods is missing to date especially for (human) biological soft tissues. This given study determined the cross-sectional areas of ten synthetic polyamide 12 and twenty-nine human iliotibial band specimens. It used the following four commonly deployed methods: caliper gauge (CG), molding compound (MC), X-ray micro computed tomography (μCT) and digital image correlation (DIC). The repeatability coefficient was calculated for the four methods and the agreement between the four methods were compared using Bland-Altman plots. All methods but CG offer consistent and reliable measurements of iliotibial band cross section determination, with no difference in their performance levels. In the polyamide specimens, cross-section determination using μCT appeared to provide the best repeatability coefficient RC (0.09 mm2 and 0.18 mm2 with reduced voxel resolution). It shows also for iliotibial band specimens the best agreements especially when compared to MC with a bias less than 1 % and limits of agreements lower ±25 %. The given data suggest that any of the given methods, μCT, MC or DIC can be used effectively for CSA measurements of soft tissues. Minor methodological discrepancies were observed exclusively in specimens with highly uniform geometries. The principal limiting factor appears to be inherent tissue-specific variability rather than the measurement precision of the applied systems. In contrast, due to systematic bias and poor concordance with all other methods investigated, CG cannot be recommended for accurate CSA determination of soft tissue specimens.
Author(s)
Werner, Michael  
Fraunhofer-Institut für Werkzeugmaschinen und Umformtechnik IWU  
Drossel, Welf-Guntram  
Fraunhofer-Institut für Werkzeugmaschinen und Umformtechnik IWU  
Löffler, Sabine
Universität Leipzig
Hammer, Niels
Fraunhofer-Institut für Werkzeugmaschinen und Umformtechnik IWU  
Journal
Journal of the mechanical behavior of biomedical materials  
Open Access
File(s)
Download (4.56 MB)
Rights
CC BY 4.0: Creative Commons Attribution
DOI
10.1016/j.jmbbm.2025.107190
10.24406/publica-5568
Additional link
Full text
Language
English
Fraunhofer-Institut für Werkzeugmaschinen und Umformtechnik IWU  
Keyword(s)
  • Cross section

  • Digital image correlation

  • Iliotibial band

  • Method comparison

  • Micro computed tomography

  • Physical dimension

  • Soft tissue biomechanics

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024