Recent improvements in the novel approach to the fast detection of surface contaminations

Abstract
Here, we present the idea behind a novel measurement system and the recent improvements in detecting surface contaminations using a tunable, very fast three-core quantum cascade laser (QCL) system. It is developed as a potential replacement for the old established double-wheel sampling system currently used to detect surface threats caused by hazardous, non-volatile chemical substances. The novel system design is based on an optical measurement principle, allowing standoff detection and identification, thus rendering ground contact unnecessary. One of the leading military requirements for a CBRN reconnaissance vehicle is a high marching speed; hence, this new system is designed to have an ultra-short acquisition time and an adequate spectral bandwidth for measurements in the mid-infrared (MIR). This innovative approach may replace the more cumbersome indirect detection techniques. We discuss the main advantages and evaluate possible application scenarios that we expect from this setup. Active IR backscatter spectroscopy generally permits the contactless identification of hazardous chemical substances on surfaces. Here, the design was optimized around an approximate measuring distance of decimeters. Using a monoaxial setup, the autofocus is less demanding than alternative approaches and even allows for rapid measurements of rough surfaces. We built the improved measurement system based on novel QCL modules that integrate micro-opto-electro-mechanical grating scanners (MOEMS) in an external cavity. These elaborate laser modules provide almost one kilohertz (kHz) spectral scan speeds and typically cover a spectral range of 200-300 cm⁻¹, respectively. Furthermore, such modules achieve measurement times of as short as one millisecond per spectrum. The full spectral coverage of the system is realized by coupling several of such modules.
Author(s)
Wilsenack, Frank
Bundeswehr Research Institute for Protective Technologies and CBRN Protection WIS
Meyer, Fabian
Bundeswehr Research Institute for Protective Technologies and CBRN Protection WIS
Flores, Yuri Victorovich
Fraunhofer-Institut für Angewandte Festkörperphysik IAF  
Härtelt, Marko  
Fraunhofer-Institut für Angewandte Festkörperphysik IAF  
Adelhardt, Mario
Bundeswehr Research Institute for Protective Technologies and CBRN Protection WIS
Ficks, Arne
Bundeswehr Research Institute for Protective Technologies and CBRN Protection WIS
Journal
The European physical journal. Plus  
Open Access
DOI
10.1140/epjp/s13360-024-05499-z
10.24406/h-477799