Abstract
Purpose: In clinical practice, many patients with right heart failure (RHF) have elevated pulmonary artery pressures and increased afterload on the right ventricle (RV). In this study, we evaluated the feasibility of RV augmentation using a soft robotic right ventricular assist device (SRVAD), in cases of increased RV afterload. Methods: In nine Yorkshire swine of 65-80 kg, a pulmonary artery band was placed to cause RHF and maintained in place to simulate an ongoing elevated afterload on the RV. The SRVAD was actuated in synchrony with the ventricle to augment native RV output for up to one hour. Hemodynamic parameters during SRVAD actuation were compared to baseline and RHF levels. Results: Median RV cardiac index (CI) was 1.43 (IQR, 1.37-1.80) L/min/m2 and 1.26 (IQR 1.05-1.57) L/min/m2 at first and second baseline. Upon PA banding RV CI fell to a median of 0.79 (IQR 0.63-1.04) L/min/m2. Device actuation improved RV CI to a median of 0.87 (IQR 0.78-1.01), 0.85 (IQR 0.64-1.59) and 1.11 (IQR 0.67-1.48) L/min/m2 at 5 min (p = 0.114), 30 min (p = 0.013) and 60 (p = 0.033) minutes respectively. Statistical GEE analysis showed that lower grade of tricuspid regurgitation at time of RHF (p = 0.046), a lower diastolic pressure at RHF (p = 0.019) and lower mean arterial pressure at RHF (p = 0.024) were significantly associated with higher SRVAD effectiveness. Conclusions: Short-term augmentation of RV function using SRVAD is feasible even in cases of elevated RV afterload. Moderate or severe tricuspid regurgitation were associated with reduced device effectiveness.
Author(s)
Wamala, I.
Children's Hospital Boston
Payne, C.J.
Harvard University
Saeed, M.Y.
Children's Hospital Boston
Bautista-Salinas, D.
Children's Hospital Boston
Story, D. van
Children's Hospital Boston
Thalhofer, Thomas  
Fraunhofer-Einrichtung für Mikrosysteme und Festkörper-Technologien EMFT  
Staffa, S.J.
Children's Hospital Boston
Ghelani, S.J.
Children's Hospital Boston
Nido, P.J. del
Children's Hospital Boston
Walsh, C.J.
Harvard University
Vasilyev, N.V.
Children's Hospital Boston
Journal
Cardiovascular engineering and technology : CVET  
Open Access
DOI
10.1007/s13239-021-00562-7
Language
English
Fraunhofer-Einrichtung für Mikrosysteme und Festkörper-Technologien EMFT  
Keyword(s)
  • Elevated pulmonary artery pressure

  • Right heart failure

  • Soft robotic ventricular assist device

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024