• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Artikel
  4. Biodegradable open-porous scaffolds made of sintered magnesium W4 and WZ21 short fibres show biocompatibility in vitro and in long-term in vivo evaluation
 
  • Details
  • Full
Options
2022
Journal Article
Title

Biodegradable open-porous scaffolds made of sintered magnesium W4 and WZ21 short fibres show biocompatibility in vitro and in long-term in vivo evaluation

Abstract
Open-porous scaffolds made of W4 and WZ21 fibres were evaluated to analyse their potential as an implant material. WZ21 scaffolds without any surface modification or coating, showed promising mechanical properties which were comparable to the W4 scaffolds tested in previous studies. Eudiometric testing results were dependent on the experimental setup, with corrosion rates differing by a factor of 3. Cytotoxicity testing of WZ21 showed sufficient cytocompatibility. The corrosion behavior of the WZ21 scaffolds in different cell culture media are indicating a selective dealloying of elements from the magnesium scaffold by different solutions. Long term in-vivo studies were using 24 W4 scaffolds and 12 WZ21 scaffolds, both implanted in rabbit femoral condyles. The condyles and important inner organs were explanted after 6, 12 and 24 weeks and analyzed. The in-vivo corrosion rate of the WZ21 scaffolds calculated by microCT-based volume loss was up to 49 times slower than the in-vitro corrosion rate based on weight loss. Intramembranous bone formation within the scaffolds of both alloys was revealed, however a low corrosion rate and formation of gas cavities at initial time points were also detected. No systemic or local toxicity could be observed. Investigations by μ-XRF did not reveal accumulation of yttrium in the neighboring tissue. In summary, the magnesium scaffold´s performance is biocompatible, but would benefit from a surface modification, such as a coating to obtain lower the initial corrosion rates, and hereby establish a promising open-porous implant material for load-bearing applications.
Author(s)
Bobe, Katharina
Willbold, Elmar
Haupt, Maike
Reebmann, Mattias
Morgenthal, Ingrid
Institutsteil Dresden
Andersen, Olaf
Institutsteil Dresden  
Studnitzky, Thomas  
Institutsteil Dresden  
Nellesen, Jens
Tillmann, Wolfgang
Vogt, Carla
Vano-Herrera, Kelim
Witte, Frank
Journal
Acta biomaterialia  
DOI
10.1016/j.actbio.2022.06.005
Language
English
Fraunhofer-Institut für Fertigungstechnik und Angewandte Materialforschung IFAM  
Keyword(s)
  • Bone defects

  • Magnesium alloy

  • Biodegradable metal

  • Temporary implant

  • Scaffold

  • Open-porous

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024