Abstract
In this paper, we propose an algorithm based on complex empirical mode decomposition with principle component analysis(CEMD-PCA) which estimates the vital parameters of stationary and moving person, irrespective of the orientation in an extreme clutter and multipath environment. The results obtained were compared against Pulse oximeter(PULOX PO-300) and fitbit wrist band and the average error of heart beat was found to be less than 1%.
Author(s)
Rudrappa, Manjunath Thindlu
Herschel, Reinhold  
Knott, Peter  
Mainwork
21st International Radar Symposium, IRS 2020  
Conference
International Radar Symposium (IRS) 2020  
DOI
10.23919/IRS48640.2020.9253928
Language
English