• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Konferenzschrift
  4. Simplified Stokes polarimeter based on division-of-amplitude
 
  • Details
  • Full
Options
2019
Conference Paper
Title

Simplified Stokes polarimeter based on division-of-amplitude

Abstract
A polarization state detector (PSD) measures the state of polarization of the detected light. The state of polarization is fully described by the Stokes vector containing four Stokes parameters. A division-of-amplitude photopolarimeter (DOAP) measures the four Stokes parameters by simultaneously acquiring four intensities using photodetectors. A key component of the DOAP is the first beam splitter, which splits up the incoming beam into two beams. The effect of the beam splitter on the state of polarization of the reflected (r) and transmitted (t) beam is determined by six parameters: R, T, PSr, PSt, Dr, and Dt. R and T are the reflectance and transmittance, and (PSr, Dr) and (PSt, Dt) are the ellipsometric parameters of the beam splitter in reflection and transmission, respectively. To measure the Stokes vector with high accuracy, the six optical parameters must be chosen appropriately. In previous work, the optimal parameters of the beam splitter have been determined as R = T = 1/2, cos2 2PSr = 1/3, PSt = p/2 - PSr, and Dr-Dt modulo p=p/2 by calculating the maximum of the absolute value of determinant of the instrument matrix. Using additional quarter-wave plates eliminates the constraint on the retardance and hence simplifies the manufacturing process of the beam splitter, especially when broadband application is intended. To compensate a suboptimal value of Dr-Dt, the azimuthal angles of the principal axes of the retarders must be adjusted, for which we provide analytic formulas. Hence, a DOAP with retarders is also optimal in the sense that the same values for the determinant and condition number of the instrument matrix are obtained. When using two additional retarders, it is necessary to install both on the same light path in order to obtain an optimal DOAP. We will show that is also possible to get an optimal DOAP with only one additional quarter-wave plate instead of two, if one of the Wollaston prisms is rotated.
Author(s)
Negara, Christian
Li, Zheng  
Längle, Thomas  
Beyerer, Jürgen  
Mainwork
Photonics and Education in Measurement Science 2019  
Conference
Conference "Photonics and Education in Measurement Science" 2019  
DOI
10.1117/12.2532399
Language
English
Fraunhofer-Institut für Optronik, Systemtechnik und Bildauswertung IOSB  
Keyword(s)
  • polarimetry

  • ellipsometry

  • stokes vector

  • polarization state detector

  • division-of-amplitude

  • beamsplitter

  • retarder

  • quarter-wave plate

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024