  4. Accuracy and Precision of Volumetric Bone Mineral Density Assessment Using Dual-source Dual-energy versus Quantitative CT: A Phantom Study
 
  • Details
  • Full
Options
2021
Journal Article
Title

Accuracy and Precision of Volumetric Bone Mineral Density Assessment Using Dual-source Dual-energy versus Quantitative CT: A Phantom Study

Abstract
Background: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). Methods: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. Results: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984-0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. Conclusions: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.
Author(s)
Koch, Vitali
Univ. Hospital Frankfurt
Große Hokamp, Nils
Univ. Hospital Cologne
Albrecht, Moritz H.
Univ. Hospital Frankfurt
Gruenewald, Leon D.
Univ. Hospital Frankfurt
Yel, Ibrahim
Univ. Hospital Frankfurt
Borggrefe, Jan
Univ. of Kiel
Wesarg, Stefan  
Fraunhofer-Institut für Graphische Datenverarbeitung IGD  
Eichler, Katrin
Univ. Hospital Frankfurt
Burck, Iris
Univ. Hospital Frankfurt
Gruber-Rouh, Tatjana
Univ. Hospital Frankfurt
Lenga, Lukas
Univ. Hospital Frankfurt
Vogl, Thomas J.
Univ. Hospital Frankfurt
Martin, Simon S.
Univ. Hospital Frankfurt
Wichmann, Julian L.
Univ. Hospital Frankfurt
Hammerstingl, Renate
Univ. Hospital Frankfurt
Alizadeh, Leona S.
Univ. Hospital Frankfurt
Mader, Christoph
Univ. Hospital Frankfurt
Huizinga, Nicole A.
Goethe Univ. of Frankfurt
D'Angelo, Tommaso
Univ. Hospital Messina
Ascenti, Giorgio
Univ. Hospital Messina
Mazziotti, Silvio
Univ. Hospital Messina
Booz, Christian
Univ. Hospital Frankfurt
Journal
European radiology experimental  
Open Access
DOI
10.1186/s41747-021-00241-1
Language
English
Fraunhofer-Institut für Graphische Datenverarbeitung IGD  
Keyword(s)
  • dual-energy CT

  • Osteoporosis

  • Lead Topic: Individual Health

  • Research Line: Computer vision (CV)

  • Research Line: Modeling (MOD)

  • bone mineral density (BMD)

  • computed tomography (CT)

  • medical imaging

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024