Tensile and fatigue evaluation of Ti-15Al-33Nb (at.%) and Ti-21Al-29Nb (at.%)alloys for biomedical applications

Abstract
In this work the fatigue and tensile behavior of Ti-15 Al-33Nb (at.%) and Ti-21 Al-29Nb (at.%) was evaluated and compared to that for other titanium-based biomedical implant alloys, in particular Ti-6Al-4V (wt.%). The mechanical properties of interest were fatigue strength, tensile strength elastic modulus, and elongat ion-to-failure. Fatigue stress versus life curves were obtained for tests performed at room temperature in air as well as in Ringer´s solution at R=0,1 for maximum stresses between 35% and 90% of ultimate tensile strength. The results indicated that the fatigue strength and lives and elastic modulus of these alloys is comparable to that for Ti-6Al-4V (wt.%). Considering the data scatter and deformation behavior, the Ringer´s solution did not significantly affect the fatigue behavior. Heat treatment reduced the tensile strength and this corresponded to a reduction in the fatigue strength. The tensile strength of the as-processed Ti-A l-Nb alloys was slightly lower than that for Ti-6Al-4V (wt.%) and the Ti-15Al-33 Nb (at.%) exhibited lower strength and higher elongations than Ti-21Al-29Nb. Based on the current results, it is proposed that titanium- aluminium-niobium alloys will be of considerable future interest for biomedical applications.
Author(s)
Boehlert, C.J.
Cowen, C.J.
Jaeger, C.R.
Niinomi, M.
Akahori, T.
Journal
Materials Science and Engineering, C. Biomimetic and supramolecular systems Biomimetic materials, sensors and systems  
DOI
10.1016/j.msec.2004.12.011
Language
English
Fraunhofer-Institut für Werkstoffmechanik IWM  
Keyword(s)
  • biomedical implant application

  • fatigue

  • strength

  • microstructure