2024
Journal Article
Title

Characterisation of a high granularity multi-channel prompt γ-ray detection system prototype for proton range verification based on the PETsys TOFPET2 ASIC

Abstract
Proton therapy requires range verification in order to exploit its full potential. One of the most promising approaches is to monitor prompt gamma-rays produced by nuclear interactions of the therapeutic particles in the patient tissues. A detector with a wide energy range from 100 keV to 15 MeV and excellent time resolution is required to achieve millimetric precision in proton range. During patient treatment, the detector count rates are usually above 106 s-1 and the fraction of pile-up events is very high for commonly used fast inorganic scintillators. We are investigating a full acceptance approach with increased granularity in order to reduce the size of the scintillators and consequently the count rate per channel. Stacking the scintillators in matrices requires suitable multi-channel photo-multipliers and a fitting acquisition system. Here, we present two geometries of CeBr3 crystals 5 × 5 × 20 mm3 and 10 × 10 × 30 mm3, together with modern silicon photo-multipliers (SiPM) adapted to work with the PETsys TOFPET2 ASIC. The TOFPET2 ASIC was developed for Time-of-Flight Positron Emission Tomography (TOF-PET) applications. Here we show its potential for higher gamma-ray energies and future hybrid imaging. First results of energy resolution of 6.1 %-7.8 % are achieved at 3.42 MeV using a 241Am9Be source. The time resolution was found to be below 100 ps and studies of the count rates and the dead time of the full system were performed. Different SiPM models are analysed for their impact on the coincidence time resolution.
Author(s)
Novgorodova, Olga
TU Dresden, Institute of Nuclear and Particle Physics
Glatte, A.
TU Dresden, Institute of Nuclear and Particle Physics
Hentges, R.
TU Dresden, Institute of Nuclear and Particle Physics
Kögler, T.
TU Dresden, Carl Gustav Carus University
Lutz, M.
Helmholtz-Zentrum Dresden-Rossendorf -HZDR-  
Roemer, K.
Helmholtz-Zentrum Dresden-Rossendorf -HZDR-  
Teichmann, Tobias
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
Straessner, A.
TU Dresden, Institute of Nuclear and Particle Physics
Weinberger, D.
Helmholtz-Zentrum Dresden-Rossendorf -HZDR-  
Journal
Journal of Instrumentation  
Open Access
DOI
10.1088/1748-0221/19/02/P02030
Additional full text version
Landing Page
Language
English
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
Keyword(s)
  • Instrumentation for hadron therapy

  • Gamma camera

  • SPECT

  • PET PET/CT

  • coronary CT angiography (CTA)

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024