Abstract
Computed laminography (CL) is an image forming method of X-ray testing that yields images of object slices by a simple linear translation of the object relative to the tube-detector system. No relative movement of the X-ray tube to the detector is needed and in contrast to classical laminography all object layers can be obtained by one scan. Moreover CL turns out to be equivalent to a computed tomography (CT) with a limited angular region, which allows the reconstruction of object slices using slightly modified CT algorithms, resulting in higher resolution compared with simple tomosynthesis in the case of classical laminography.
Author(s)
Gondrom, S.
Zhou, J.
Maisl, M.
Reiter, H.
Kröning, M.
Arnold, W.
Journal
Nuclear Engineering and Design  
DOI
10.1016/S0029-5493(98)00319-7
Language
English
Fraunhofer-Institut für Zerstörungsfreie Prüfverfahren IZFP  
Keyword(s)
  • x-ray-computed laminography

  • computed tomography