Enhanced absolute accuracy of an industrial milling robot using stereo camera system

Abstract
In this publication an approach for increasing the absolute positioning accuracy of an industrial milling robot with help of a stereo camera system is presented. To measure the position and orientation of the robot tool center point, a specific adapter with retro reflective markers is mounted on the spindle. The calculation of the transformation of this target holder to the robot tool is part of this paper along with the calibration from the robot to the camera system. These datasets serve as the basis of a static pose control, where the robot absolute accuracy errors will be greatly reduced.
Author(s)
Möller, C.
Schmidt, H.C.
Shah, N.H.
Wollnack, J.
Journal
Procedia Technology  
Conference
International Conference on System-Integrated Intelligence (SysInt) 2016  
Open Access
DOI
10.1016/j.protcy.2016.08.050