• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Artikel
  4. Electrode placement for SEEG: Combining stereotactic technique with latest generation planning software for intraoperative visualization and postoperative evaluation of accuracy and accuracy predictors
 
  • Details
  • Full
Options
2022
Journal Article
Title

Electrode placement for SEEG: Combining stereotactic technique with latest generation planning software for intraoperative visualization and postoperative evaluation of accuracy and accuracy predictors

Abstract
Background Intracranial recordings with stereoelectroencephalography (SEEG) aims at defining the epileptogenic zone in patients with pharmacoresistant epilepsy. Currently used techniques for depth electrode implantation include stereotactic frame-based and navigated frameless applications, both either conventional or robot-assisted. Safety and diagnostic effectiveness depend on accuracy of implantation. Objective To evaluate the planning experience, accuracy of stereotactic electrode placement as well as accuracy predictors with the use of latest generation planning software. Methods Retrospective study of 15 consecutive patients who received depth electrodes using the Leksell stereotactic frame, after planning with Elements (Brainlab, Munich, Germany). For each electrode, we calculated the entry point error (EPE) as lateral deviation and target point error (TPE) both as lateral deviation and distance to tip. Multivariate regression analysis and computation of 95% confidence intervals using the bootstrap method were applied for statistical analysis and evaluation of accuracy predictors. Results The mean EPE, lateral deviation at TP and distance to tip at TP were 0.6 0.5 mm, 1.1 0.7 mm and 1.5 0.8 mm respectively. Order of implantation (1-6 vs. >6) is predictor for distance to tip at TP and length of electrode predictor for the lateral deviation at TP. Localization of electrode generally did not correlate to error, but insular electrodes were significantly less accurate than lobar ones. Conclusion Combination of frame-based stereotaxy with latest generation planning software may offer a better planning and implantation experience. Accuracy predictors should be analyzed and be considered for the improvement of accuracy and safety of SEEG implantation methods.
Author(s)
Kogias, Evangelos
Altenmüller, Dirk-Matthias
Karakolios, Kleanthis
Egger, Karl
Coenen, Volker Arnd
Schulze-Bonhage, Andreas
Reinacher, Peter Christoph  
Fraunhofer-Institut für Lasertechnik ILT  
Journal
Clinical neurology and neurosurgery  
DOI
10.1016/j.clineuro.2022.107137