• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Artikel
  4. Rapid switching and durable on-chip spark-cavitation-bubble cell sorter
 
  • Details
  • Full
Options
2022
Journal Article
Title

Rapid switching and durable on-chip spark-cavitation-bubble cell sorter

Abstract
Precise and high-speed sorting of individual target cells from heterogeneous populations plays an imperative role in cell research. Although the conventional fluorescence-activated cell sorter (FACS) is capable of rapid and accurate cell sorting, it occupies a large volume of the instrument and inherently brings in aerosol generation as well as cross-contamination among samples. The sorting completed in a fully enclosed and disposable microfluidic chip has the potential to eliminate the above concerns. However, current microfluidic cell sorters are hindered by the high complexities of the fabrication procedure and the off-chip setup. In this paper, a spark-cavitation-bubble-based fluorescence-activated cell sorter is developed to perform fast and accurate sorting in a microfluidic chip. It features a simple structure and an easy operation. This microfluidic sorter comprises a positive electrode of platinum and a negative electrode of tungsten, which are placed on the side of the main channel. By applying a high-voltage discharge on the pair of electrodes, a single spark cavitation bubble is created to deflect the target particle into the downstream collection channel. The sorter has a short switching time of 150 μs and a long lifespan of more than 100 million workable actions. In addition, a novel control strategy is proposed to dynamically adjust the discharge time to stabilize the size of the cavitation bubble for continuous sorting. The dynamic control of continuously triggering the sorter, the optimal delay time between fluorescence detection and cell sorting, and a theoretical model to predict the ideal sorting recovery and purity are studied to improve and evaluate the sorter performance. The experiments demonstrate that the sorting rate of target particles achieves 1200 eps, the total analysis throughput is up to 10,000 eps, the particles sorted at 4000 eps exhibit a purity greater than 80% and a recovery rate greater than 90%, and the sorting effect on the viability of HeLa cells is negligible.
Author(s)
Jiao, Zeheng
Tsinghua University, Beijing  
Han, Yong
Tsinghua University, Beijing  
Zhao, Jingjing
Stanford University, Stanford, CA, USA
Chao, Zixi
Tsinghua University, Beijing  
Tárnok, Attila  
Fraunhofer-Institut für Zelltherapie und Immunologie IZI  
You, Zheng
Tsinghua University, Beijing  
Journal
Microsystems & nanoengineering  
Open Access
DOI
10.1038/s41378-022-00382-2
Additional link
Full text
Language
English
Fraunhofer-Institut für Zelltherapie und Immunologie IZI  
Keyword(s)
  • Electrical and electronic engineering

  • Microfluidics

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024