Gerber, P.P.GerberZilly, B.B.ZillyTeipel, U.U.Teipel2022-03-092022-03-091998https://publica.fraunhofer.de/handle/publica/330461A wet grinding process with a rotor-stator mill was selected for safe grinding of the explosive .epsilon.-CL-20 with a mean particle size of 200 .mu.m to produce a narrow particle size distribution and a mean particle size of 5 .mu.m. The aq. suspension had a solid concn. of 15 per cent. The obtained particle size distribution of .epsilon. -CL-20 is compared to that of RDX.en660Fine grinding of explosivesFeinzerkleinerung von Explosivstoffenconference paper