Krehl, P.P.KrehlWarken, D.D.Warken2022-03-082022-03-081990https://publica.fraunhofer.de/handle/publica/317537Radiography of liquid fuel injection provides valuable information on the jet development, structure, propagation and disintegration which cannot be obtained optically, because often the jet core is hidden behind a curtain of spray droplets. Tests at increasing prepressures require thicker x-ray windows in the injection chamber which absorb already most of the transmitted soft x-rays. The technique encompasses a high-intensity flash soft x-ray generator with a pulse duration of 120 ns FWHM and a specially designed injection chamber. Various flash radiographs of liquid injection phenomena, taken at a prepressure of 1 and 100 bars, illustrate the achieved progress.enchamber prepressurecontrast improvementEinspritzvorgängeflash soft x-ray generatorinjection phenomenajet breakup mechanismKammervordruckKontrastverbesserungsoft flash radiographyStrahlauflösungweiche Röntgenblitz-Radiographieweiche Röntgenblitzquelle620Flash soft radiography - its adapting to the study of breakup mechanisms of liquid jets into a high-density gasWeiche Röntgenblitz-Radiographie und deren Anwendung auf die Untersuchung der Einspritzvorgänge von Flüssigkeitsstrahlen in ein dichtes Gasconference paper