Reiter, H.H.ReiterArm, P.P.Arm2022-03-092022-03-091995https://publica.fraunhofer.de/handle/publica/324757A sonic investigation of the potential of the ComScan system concerning the contrast resolution and depth resolution of concrete and steel reinforced concrete give the following results: The localisation and determination of the depth of the steel reinforcement in concrete can be performed with the ComScan system up to a depth of 50 mm. The size and geometry of aggregates can only be described in areas near the surface. In these areas the system detects pores of a size of 0.5 mm. Pores of a size of 1 mm can be detected to a depth of 20 mm. The moisture in concrete gives only a small signal. The resolution of the system can be improved by a reconstruction of the density distribution layer by layer.deArmierungBetonconcreteFeuchtigkeitmoisturenondestructive testingporereconstructionreinforcementRekonstruktionRöntgenRückstreuungscatteringx-rayZerstörungsfreie Prüfung620658670Potential der ComScan-Technik zur Charakterisierung von Betonconference paper