Abstract
A demagnetization study was conducted on a magnetically shielded room (MSR) at Fraunhofer IPM, designed for applications such as magnetoencephalography (MEG) and material testing. With a composite of two layers of mu-metal and an intermediate aluminum layer, the MSR must provide a residual field under 5 nT for the successful operation of optically pumped magnetometers (OPMs). The degaussing process, employing six individual coils, reached the necessary residual magnetic field within the central 1 m3 volume in under four minutes. Due to the low-frequency shielding factor of 100, the obtained average residual field is shown to be limited by environmental residual field changes after degaussing and not by the degaussing procedure.
Author(s)
Koss, Peter  
Fraunhofer-Institut für Physikalische Messtechnik IPM  
Voigt, Jens
Rasser, Ronja  orcid-logo
Fraunhofer-Institut für Physikalische Messtechnik IPM  
Schnabel, Allard
Journal
Materials  
Open Access
DOI
10.3390/ma17235877
Language
English
Fraunhofer-Institut für Physikalische Messtechnik IPM  
Keyword(s)
  • Degaussing

  • Residual magnetic field

  • Shielding

  • OPM

  • MEG

  • Magnetically shielded room

  • Magnetoencephalography

  • Optically pumped magnetometers

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024