• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Artikel
  4. Sensitivity maps for time-reverse imaging: An accuracy study for the Los Humeros Geothermal Field (Mexico)
 
  • Details
  • Full
Options
2020
Journal Article
Title

Sensitivity maps for time-reverse imaging: An accuracy study for the Los Humeros Geothermal Field (Mexico)

Abstract
The estimation of the source-location accuracy of microseismic events in reservoirs is of significant importance. Time-reverse imaging (TRI) provides a highly accurate localization scheme to locate events by time-reversing the recorded full wavefield and back propagating it through a velocity model. So far, the influence of the station geometry and the velocity model on the source-location accuracy is not well known. Therefore, sensitivity maps are developed using the geothermal site of Los Humeros in Mexico to evaluate the spatial variability of the source-location accuracy. Sensitivity maps are created with an assumed gradient velocity model with a constant vp-vs ratio and with a realistic velocity model for the region of Los Humeros. The positions of 27 stations deployed in Los Humeros from September 2017 to September 2018 are used as surface receivers. An automatic localization scheme is proposed that does not rely on any a priori information about the sources and thus negates any user bias in the source locations. The sensitivity maps are created by simulating numerous uniformly distributed sources simultaneously and locating these sources using TRI. The found source locations are compared to the initial source locations to estimate the achieved accuracy. The resulting sensitivity maps show that the station geometry introduces complex patterns in the spatial variation of accuracy. Furthermore, the influence of the station geometry on the source-location accuracy is larger than the influence of the velocity model. Finally, a microearthquake recorded at the geothermal site of Los Humeros is located to demonstrate the usability of the derived sensitivity maps. This study stresses the importance of optimizing station networks to enhance the accuracy when locating seismic events using TRI.
Author(s)
Finger, Claudia  orcid-logo
Saenger, Erik  orcid-logo
Journal
Geophysical journal international  
Open Access
DOI
10.1093/gji/ggaa160
Additional full text version
Landing Page
Language
English
Fraunhofer-Einrichtung für Energieinfrastrukturen und Geothermie IEG  
  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024