1985
Journal Article
Titel

Electromagnetic ultrasonic testing

Abstract
An overview is given of the EMUS transduction technique, its physical foundations, transducer construction, laboratory developments and applications. The flexibility in transducer construction permits the excitation of a large variety of bulk waves and guided wave modes. Important application fields for the EMUS transducers are nondestructive testing with Rayleigh waves, SH waves and shear waves with normal incidence since, for these wave types, conventional excitation through a couplant suffers serious drawbacks.
Author(s)
Höller, P.
Wilbrand, A.
Zeitschrift
Traitement du Signal
Thumbnail Image
Language
English
google-scholar
Fraunhofer-Institut für Zerstörungsfreie Prüfverfahren IZFP
Tags
  • EMAT

  • EMUS

  • magneto-acoustic conv...

  • surface wave