• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Scopus
  4. Validation of the EmotiBit wearable sensor for heart-based measures under varying workload conditions
 
  • Details
  • Full
Options
2025
Journal Article
Title

Validation of the EmotiBit wearable sensor for heart-based measures under varying workload conditions

Abstract
Introduction: The EmotiBit photoplethysmography (PPG) device allows user-owned data collection for measures of cardiovascular activity (CVA) and electrodermal activity (EDA) in naturalistic settings. The aim of this study was to evaluate the validity of this device for collecting high-quality data while participants experience varying levels of cognitive workload.
Methods: Using a standardized criterion validity protocol, recordings of 15 participants performing a cognitive workload task were compared for the EmotiBit and a reference electrocardiography (ECG) device (BITalino PsychoBit). Multiple preprocessing pipelines and a signal quality check were implemented. Parameters of interest including heart rate (HR), heart rate variability (HRV) measures, skin conductance level (SCL), and skin conductance response (SCR) measures were assessed using Bland-Altman plot and ratio (BAr) analyses, as well as cross-correlations of the EDA signal time series of both devices.
Results: BAr results indicated good agreement between devices regarding HR with an average difference of 1–2 beats per minute (bpm). HRV measures yielded an insufficient BAr, albeit most data points lay within a priori boundaries of agreement. EDA measures yielded insufficient agreement for comparing SCL and SCR number and amplitude.
Discussion: The results are comparable to the validation of similar wearable PPG devices and extend the validation of the EmotiBit by assessing the acquired signals during varying levels of cognitive workload. While the device may be used to collect HR for scientific data analysis, its quality regarding HRV and EDA measures is not comparable to a standard ECG.
Significance: This study provides the first systematic validation following a standardized protocol of the EmotiBit PPG device relative to an ECG when considering recordings collected during cognitive workload induction.
Author(s)
Vorreuther, Anna
Univ. Stuttgart, Institut für Arbeitswissenschaft und Technologiemanagement -IAT-  
Tagalidou, Nektaria  
Univ. Stuttgart, Institut für Arbeitswissenschaft und Technologiemanagement -IAT-  
Vukelic, Mathias  
Fraunhofer-Institut für Arbeitswirtschaft und Organisation IAO  
Journal
Frontiers in neuroergonomics  
Project(s)
Beanspruchungsgerechte Rotationsplanung in Produktion und Logistik  
KI-Fortschrittszentrum »Lernende Systeme und Kognitive Robotik«  
Funder
Bundesministerium für Bildung und Forschung -BMBF-  
Baden-Württemberg, Ministerium für Wirtschaft, Arbeit und Wohnungsbau  
Open Access
File(s)
Download (8.27 MB)
Rights
CC BY 4.0: Creative Commons Attribution
DOI
10.3389/fnrgo.2025.1585469
10.24406/h-490263
Additional link
Full text
Language
English
Fraunhofer-Institut für Arbeitswirtschaft und Organisation IAO  
Keyword(s)
  • photoplethysmography

  • electrocardiography

  • electrodermal activity

  • heart rate

  • skin conductance

  • cognitive workload

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024