Repeatability of Phase‐Resolved Functional Lung (PREFUL)‐MRI Ventilation and Perfusion Parameters in Healthy Subjects and COPD Patients

Abstract
Background: Free‐breathing phase‐resolved functional lung (PREFUL)‐MRI may be useful for treatment monitoring in chronic obstructive pulmonary disease (COPD) patients with dyspnea. PREFUL test-retest reliability is essential for clinical application. Purpose: To measure the repeatability of PREFUL‐MRI ventilation (V) and perfusion (Q) parameters. Study Type: Retrospective and prospective. Population: A total of 28 COPD patients and 57 healthy subjects. Field Strength/Sequence. 1.5T MRI/2D spoiled gradient echo imaging. Assessment: V and Q lung parameter maps based on three coronal slices were obtained at baseline and after 14 days (COPD patients) or after a short pause outside the scanner (healthy subjects). Regional ventilation (RVent) and imaging flow volume loops by cross‐correlation (ccVent) were quantified. Q was normalized to the signal of the main pulmonary artery (QN) and quantified (QQuant). Pulmonary pulse wave transit time (pPTT), voxel‐by‐voxel (regional), and whole lung (global) ventilation defect percentage based on RVent (VDPRVent) and ccVent (VDPccVent), perfusion defect percentage (QDP), and ventilation/perfusion match based on RVent (VQMRVent) and ccVent (VQMccVent) were calculated. Statistical Tests: Regional V and Q were analyzed globally for each subject. Each parameter's median of scans 1 and 2 were assessed by Wilcoxon sign rank test. A parameter's repeatability was analyzed by Bland-Altman analyses, coefficients of variation, intraclass correlation coefficients (ICC), and power calculations. The regional voxel repeatability was examined by calculating the Sørensen-Dice coefficient. Results: There was no bias and no significant differences between the first and second MRI for any parameters (P > 0.05). Coefficient of variation ranged from 2.26% (ccVent) to 19.31% (QDP), ICC from 0.93 (QDP) to 0.60 (pPTT), the smallest detectable difference was 0.002 ccVent. Regional comparison showed the highest overlap (84%) in VDPRVent in healthy voxels and the lowest (53%) in VDPccVent defect voxels. Data Conclusion: V and Q PREFUL‐MRI parameters were repeatable over two scan sessions in both healthy controls and COPD patients.
Author(s)
Pöhler, G.H.
Klimes, F.
Behrendt, L.
Voskrebenzev, A.
Gonzalez, C.C.
Wacker, F.
Hohlfeld, J.M.
Vogel-Claussen, J.
Zeitschrift
Journal of magnetic resonance imaging
Thumbnail Image
DOI
10.1002/jmri.27385
Externer Link
Externer Link
Language
English
google-scholar
Fraunhofer-Institut für Toxikologie und Experimentelle Medizin ITEM
  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Send Feedback
© 2022