Determining the Required Cleanliness Level Using Synthetic Test Contamination

Abstract
As electrification in the automotive industry progresses, the demand is rising for test particles with specific properties. More and more new applications are also being developed, such as processes for validating cleaning steps, contamination tracking or determining cleanliness limits. This article describes how test particles can be reproducibly manufactured in all three dimensions by micro milling. In addition, it explains how the dimensional accuracy of these free-form surfaces can be analyzed with computer tomography.
Author(s)
Brag, Patrick  
Fraunhofer-Institut für Produktionstechnik und Automatisierung IPA  
Piotter, Volker
Karlsruher Institut für Technologie KIT
Plewa, Klaus
Karlsruher Institut für Technologie KIT
Umbach, Sascha
Universität Kassel
Herzfeldt, Mirko
IST Prüftechnik GmbH
Mainwork
9th Manufacturing Engineering Society International Conference, MESIC 2021  
Conference
Manufacturing Engineering Society (MESIC International Conference) 2021  
Open Access
DOI
10.1088/1757-899X/1193/1/012072
Additional link
Full text
Language
English
Fraunhofer-Institut für Produktionstechnik und Automatisierung IPA  
Keyword(s)
  • technische Sauberkeit

  • Computertomographie

  • Partikel