  4. Method for the use of polymer beads as dosimeters for low-energy electron irradiation
 
  • Details
  • Full
Options
December 23, 2024
Journal Article
Title

Method for the use of polymer beads as dosimeters for low-energy electron irradiation

Abstract
In this study, a novel bead-based dosimetry system was developed. This approach uses suspended polymethyl methacrylate beads, which experience a dose-dependent change in fluorescence intensities. The beads were diluted in deionized water and exposed to low-energy electron irradiation. Afterward, the beads were analyzed by flow cytometry. The mean fluorescence of these beads increased with the radiation dose in the range of 10-50 kGy. Thus, flow cytometric fluorescence measurements allow dose mapping: the signal of each bead could be assigned to a corresponding dose. The correlation between the dose and fluorescence intensity of the beads was previously examined by irradiation using a high-energy electron beam. The presented method shows potential for dosimetry in liquids for quality control in biotechnological or pharmaceutical applications using low-energy electron irradiation as the method is easy to handle, not limited to solid-state geometry, and suitable for static and dynamic irradiation setups of liquids. This novel method provides information about the dose distribution in the investigated volume of liquid by analyzing individual beads. This provides information about average, minimum, and maximum dose values, as well their actual distribution function, which is a big advantage over other methods of liquid dosimetry, where only the mean value can be obtained.
Author(s)
Besecke, Joana Kira
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
Kenner, Lysann
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
Poremba, Andre  
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
Schönfelder, Jessy  
Fraunhofer-Institut für Zelltherapie und Immunologie IZI  
Teichmann, Tobias
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
Thoma, Martin  
Fraunhofer-Institut für Produktionstechnik und Automatisierung IPA  
Grunwald, Thomas  
Fraunhofer-Institut für Zelltherapie und Immunologie IZI  
Hauff, Elizabeth von  
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
König, Ulla  
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
Poppe, Björn
Universität Oldenburg
Schopf, Simone
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
Journal
Frontiers in physics  
Open Access
DOI
10.3389/fphy.2024.1490048
Language
English
Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik FEP  
Fraunhofer-Institut für Zelltherapie und Immunologie IZI  
Fraunhofer-Institut für Produktionstechnik und Automatisierung IPA  
Keyword(s)
  • Dosimetry

  • Liquid dosimeters

  • Fluorescence

  • Beads

  • Low-energy electron irradiation

  • Process monitoring