2013
Journal Article
Title

Characterization and simulation of peristaltic micropumps

Abstract
The aim of the work is to find an analytical model of a pneumatic micropump which was integrated into a cell-culture system. This allows the estimation of peak velocities and wall-shear stress influencing the cultured cells in our multi-organ-chip (MOC) with respect to the applied pressure and the geometric properties of the pump. By adjusting those parameters, one can imitate physiological or pathological heart activity. The calculated flow within the MOC was compared to experimental results obtained via the non-invasive micro-PIV method.
Author(s)
Busek, M.
Nötzel, M.
Polk, C.
Sonntag, F.
Journal
Journal of sensors and sensor systems : JSSS  
Open Access
DOI
10.5194/jsss-2-165-2013
Additional link
Full text
Language
English
Fraunhofer-Institut für Werkstoff- und Strahltechnik IWS  