Abstract
As global efforts on the electrification of the built environment intensify, buildings are expected to become energy-flexible and provide different services to the grid, including onsite electricity generation. Distributed energy sources such as building-integrated photovoltaics (BIPV) have a key role to play in this transition. Thus, it is essential for building professionals to use accurate and reliable tools to predict the energy performance of these installations. BIPV refers to photovoltaic systems that can replace conventional building components. The electrical performance of BIPV can differ from that of conventional PV due to their tilt angles, poorer rear ventilation, and partial shading by the surroundings. The objective of this study is to review existing performance models and evaluate their applicability to BIPV. In this study, the performance of a 5.3 kWp south-east facing BIPV rainscreen system of an institutional building was evaluated for one year on the basis of monitored data. High-resolution meteorological, electrical, and surface temperature data were collected and analysed. A model was created based on the BIPV system specifications using the NREL System Advisor Model (SAM). The analysis revealed that SAM can generate accurate and reliable data when it comes to predicting the electricity-generating and temperature behaviour of a BIPV façade, with an overall coefficient of determination (R<sup>2</sup>) ranging from 48 to 95%, depending on the simulation timestep used.
Author(s)
Jazouli, Soukaïna
University of Waterloo
Wilson, Helen Rose  
Fraunhofer-Institut für Solare Energiesysteme ISE  
Eisenlohr, Johannes
Fraunhofer-Institut für Solare Energiesysteme ISE  
Kapsis, Costa
University of Waterloo
Mainwork
Environmental Science and Engineering
Funder
Bundesministerium für Wirtschaft und Klimaschutz  
Conference
5th International Conference on Building Energy and Environment, COBEE 2022
DOI
10.1007/978-981-19-9822-5_129
Language
English
Fraunhofer-Institut für Solare Energiesysteme ISE  
Keyword(s)
  • BIPV

  • Building-integrated photovoltaics

  • Electrification

  • Energy performance

  • SAM

  • System advisor model

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024