Abstract
Ideal artificial bone grafts aim for multiscale porosity, high mechanical strength and ensure rapid vascularization for bone ingrowth. In this work modular ceramic arteriovenous loops (AV-loops) with a hierarchical porosity approach were designed and manufactured to meet these criteria and to exceed the poor mechanical strength of monolithic scaffolds. Bioactive building blocks (v-TCP, HAp, BCP) with dimensions of 1.5-3.0 mm were prepared by injection molding and assembled to complex AV-loop scaffolds using a customized automated assembly technology (pick and place). The building blocks were bonded with a biocompatible adhesive. Single building blocks are characterized by a compressive strength of 112.4-134.5 MPa with a residual sintering porosity of 32.2-41.5%, matching the strength of cortical bone of 100-230 MPa. The compressive strength of the modular assemblies varied between 22.3 and 47.6 MPa primary depending on the building block arrangement. The achieved compressive strengths are superior to current monolithic AV-scaffolds and sufficient for the implantation as non-load-bearing AV-loop scaffolds in isolation chambers. The modular AV-loop scaffolds provide a hierarchical interconnected pore network (P = 58.8%) combining small macropores of 4.1-4.3 µm size for possible enhanced protein absorption and large gradient macropores of 200-1700 µm size for optimum vascularization and complete bone ingrowth. The modular building block approach allows to design patient individualized scaffolds with complex hierarchical pore networks. The pore volume, size and geometry as well as the biological response can effectively be tuned by changing the dimensions, shape and placing gap of the bioactive building blocks.
Author(s)
Biggemann, Jonas
Friedrich-Alexander Universität Erlangen-Nürnberg
Pezoldt, Marc  
Fraunhofer-Institut für Keramische Technologien und Systeme IKTS  
Stumpf, Martin
Friedrich-Alexander Universität Erlangen-Nürnberg
Greil, Peter
Friedrich-Alexander Universität Erlangen-Nürnberg
Fey, Tobias
Friedrich-Alexander Universität Erlangen-Nürnberg / Technische Universität Nagoya
Journal
Acta biomaterialia  
DOI
10.1016/j.actbio.2018.09.008
Language
English
Fraunhofer-Institut für Keramische Technologien und Systeme IKTS  
Keyword(s)
  • bone replacement material

  • modular AV-loop

  • bioactive ceramic

  • building block

  • pick and place