• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Konferenzschrift
  4. Performance specification of areal surface texture instruments exemplified by a self-built WLI
 
  • Details
  • Full
Options
2020
Conference Paper
Title

Performance specification of areal surface texture instruments exemplified by a self-built WLI

Abstract
The calibration of optical surface topography measuring instruments ensures the comparability of the resulting surface topographies. Such comparability is also desirable for self-built optical microscopes in order to optimize these instruments with regard to their systematic and stochastic measurement uncertainty. However, there is not yet a fixed set of standards in the field of interference microscopy as in the field of stylus instruments that describes methods for their calibration, verification, adjustment and performance specification [1] [2]. The associated standard for optical measuring instruments is still in preparation in the corresponding ISO working group. There is the guideline according to VDI/VDE 2655 Sheet 1.1, for the calibration of interference microscopes for surface texture measurement. This guideline is essentially a transfer of methods that origin from the calibration of stylus instruments [1]. Thus, it describes a profile-like calibration and does specifically consider areal properties of interference microscopes. The field of areal calibration is still work in progress in the international standardization. The ISO 25178-600 that was recently published defines the basic metrological characteristics of areal surface topography measuring instruments [3]. In our study, we describe the optimization and performance specification of a self-built white light interference microscope based on methods that were developed for instrument calibration. For the performance specification we use the metrological characteristics of ISO 25178-600 that are imaged with the help of a previously developed Universal Calibration Artefact for areal calibration [4]. The results of the metrological characteristics are compared with a commercially available white light interferometer (WLI).
Author(s)
Bulun, Georgis
Technische Univ. Kaiserslautern (Germany)
Eifler, Matthias
Technische Univ. Kaiserslautern (Germany)
Hering, Julian
Technische Univ. Kaiserslautern (Germany)
Freymann, Georg von  
Fraunhofer-Institut für Techno- und Wirtschaftsmathematik ITWM  
Seewig, Jörg
Technische Univ. Kaiserslautern (Germany)
Mainwork
Interferometry XX  
Conference
Interferometry Conference 2020  
DOI
10.1117/12.2567666
Language
English
Fraunhofer-Institut für Techno- und Wirtschaftsmathematik ITWM  