• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Scopus
  4. Advancements in Camera-Based Oxygen Desaturation Monitoring in Sleep Apnea Patients
 
  • Details
  • Full
Options
2026
Conference Paper
Title

Advancements in Camera-Based Oxygen Desaturation Monitoring in Sleep Apnea Patients

Abstract
Recurrent apneic episodes lead to a decrease in blood oxygen levels and eventually hypoxemia. Persistent hypoxemic SpO values during sleep are linked to severe health risks, including organ damage, heart failure, tachycardia, and shortness of breath. Oxygen desaturation events are usually detected during polysomnography (PSG) in sleep laboratories. A PSG involves a high number of contact-based sensors, which may lead to patient discomfort and biased measurement results. In this work, a contactless camera-based oxygen desaturation monitoring method based on the analysis of multispectral videos is proposed. The method is built on the extraction and analysis of remote photoplethysmography (rPPG) signals at wavelengths of 780 and 940 nm from the forehead and a breath temperature signal via far-infrared (FIR) thermography from the subnasal region. A manual feature extraction is implemented to gather pertinent medical and physiological parameters from the obtained signals. These parameters are used to design a fully connected feed-forward neural network-based classifier, which distinguishes between periods with and without desaturation. A patient dataset consisting of 23 sleep apnea patients is collected for evaluation. The classification accuracy between desaturation events and periods without a desaturation based on the leave-one-patient-out cross-validation metric is 95.4%. The oxygen desaturation index (ODI) is estimated with a mean average error (MAE) of 2.9 , while a correct ODI stage prediction is given for 21 of the 23 patients. The regression of the exact SpO value during desaturation results in an MAE of 1.79%.
Author(s)
Alic, Belmin
Universität Duisburg-Essen
Liao, Wang
Technische Universität Ilmenau
Tauber, Samuel
Fraunhofer-Institut für Mikroelektronische Schaltungen und Systeme IMS  
Zhang, Chen
Technische Universität Ilmenau
Dietz-Terjung, Sarah
Medizinischen Fakultät
Wildenauer, Alina
Medizinischen Fakultät
Sucre, Jose Guillermo Ortiz
Medizinischen Fakultät
Weinreich, Gerhard
Medizinischen Fakultät
Sutharsan, Sivagurunathan
Medizinischen Fakultät
Schoebel, Christoph
Medizinischen Fakultät
Notni, Günther
Technische Universität Ilmenau
Viga, Reinhard
Universität Duisburg-Essen
Wiede, Christian  
Fraunhofer-Institut für Mikroelektronische Schaltungen und Systeme IMS  
Seidl, Karsten  
Fraunhofer-Institut für Mikroelektronische Schaltungen und Systeme IMS  
Mainwork
Biomedical Engineering Systems and Technologies. Revised Selected Papers  
Conference
International Joint Conference on Biomedical Engineering Systems and Technologies 2024  
DOI
10.1007/978-3-031-96899-0_14
Language
English
Fraunhofer-Institut für Mikroelektronische Schaltungen und Systeme IMS  
Keyword(s)
  • Camera-based

  • Contactless

  • Desaturation monitoring

  • Feature extraction

  • Oxygen saturation

  • Remote photoplethysmography

  • Sleep apnea

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024