• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Artikel
  4. Comparison of material measures for areal surface topography measuring instrument calibration
 
  • Details
  • Full
Options
2020
Journal Article
Title

Comparison of material measures for areal surface topography measuring instrument calibration

Abstract
The calibration of areal surface topography measuring instruments is a topic that is currently under discussion in international standard committees and a specification standard that defines the so-called 'metrological characteristics' has been published. For the broad industrial adoption of the metrological characteristics for calibration, however, clear and easy-to-apply calibration guidelines are required. Thus, a single-sample calibration artefact has been developed which allows the determination of the standardised metrological characteristics. In order to promote the adoption of the metrological characteristics calibration framework, measurements of the material measures with different instruments have been conducted and the results are presented. We report early work on the uncertainty of the comparison results and discuss systematic deviations between the various surface topography measuring instruments.
Author(s)
Eifler, M.
Institute for Measurement and Sensor Technology MTS, Technische Universität Kaiserslautern, Germany, Opti-Cal GmbH, Kaiserslautern, Germany
Hering, J.
Opti-Cal GmbH, Kaiserslautern, Germany, Physics Department and State Research Center Optimas, Technische Universität Kaiserlautern, Germany
Seewig, J.
Institute for Measurement and Sensor Technology MTS, Technische Universität Kaiserslautern, Germany, Opti-Cal GmbH, Kaiserslautern, Germany
Leach, R.K.
Manufacturing Metrology Team, University of Nottingham, United Kingdom
Freymann, Georg von
Opti-Cal GmbH, Kaiserslautern, Germany, Physics Department and State Research Center OPTIMAS, Technische Universität Kaiserslautern, Germany, Fraunhofer Institute for Industrial Mathematics ITWM, Kaiserslautern, Germany
Hu, X.
Precision Engineering Division, Physikalisch-Technische Bundesanstalt Braunschweig, Germany
Dai, G.
Precision Engineering Division, Physikalisch-Technische Bundesanstalt Braunschweig, Germany
Journal
Surface topography  
Funder
Deutsche Forschungsgemeinschaft DFG  
Open Access
DOI
10.1088/2051-672X/ab92ae
Language
English
Fraunhofer-Institut für Techno- und Wirtschaftsmathematik ITWM  
Keyword(s)
  • roughness

  • areal surface texture measurement

  • calibration

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024