• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Konferenzschrift
  4. Rapid thickness measurement with a SLAPCOPS-based terahertz TDS system
 
  • Details
  • Full
Options
2019
Conference Paper
Title

Rapid thickness measurement with a SLAPCOPS-based terahertz TDS system

Abstract
Terahertz time-domain spectroscopy traditionally requires either one mode-locked laser and an external delay line or two mode-locked lasers with a controllable repetition rate difference. Here we demonstrate a polarization-multiplexed single-laser system, which combines the benefits of both approaches without any external delay line. The fiber laser emits two pulse trains with independently adjustable repetition rates, utilizing only one laser-active section and one pump diode. With a standard fiber-coupled terahertz setup, we are able to measure transients with a spectral bandwidth of 2.5 THz and a dynamic range of 50 dB in a measurement time of 1 s. An additional benefit of the underlying concept is the possibility for the rapid measurement of very thick samples usually not possible with traditional single-laser systems.
Author(s)
Kolano, Michael
Fraunhofer-Institut für Techno- und Wirtschaftsmathematik ITWM  
Boidol, Oliver  
Fraunhofer-Institut für Techno- und Wirtschaftsmathematik ITWM  
Molter, Daniel  
Fraunhofer-Institut für Techno- und Wirtschaftsmathematik ITWM  
Freymann, Georg von  
Fraunhofer-Institut für Techno- und Wirtschaftsmathematik ITWM  
Mainwork
44th International Conference on Infrared, Millimeter, and Terahertz Waves, IRMMW-THz 2019  
Conference
International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) 2019  
DOI
10.1109/IRMMW-THz.2019.8873962
Language
English
Fraunhofer-Institut für Techno- und Wirtschaftsmathematik ITWM  
Keyword(s)
  • mode-locked laser

  • external delay line

  • controllable repetition rate difference

  • polarization-multiplexed single-laser system

  • fiber laser

  • independently adjustable repetition rates

  • laser-active section

  • standard fiber-coupled terahertz setup

  • measurement time

  • rapid measurement

  • traditional single-laser systems

  • rapid thickness measurement

  • SLAPCOPS-based terahertz TDS system

  • terahertz time-domain spectroscopy

  • frequency 2.5 THz

  • noise figure 50.0 dB

  • time 1.0 s