Options
2013
Journal Article
Title
Investigation into emissions from internal doors relevant to indoor air in order to assess the behavior of building products with respect to hygiene, health and environmental protection
Other Title
Untersuchung der raumluftrelevanten Emissionen von Innentüren zur Bewertung des Verhaltens von Bauprodukten in Bezug auf Hygiene, Gesundheit und Umweltschutz
Abstract
As part of a research project door leaves and door frames as specified in DIN EN 14351-2 have for the first time been comprehensively investigated by the test chamber method with regard to emissions relevant to indoor air. Tests were conducted in both the 1 m³ test chamber and a walk-in 24 m³ test chamber. Evaluation of results with respect to indoor-air hygiene is based on the German AgBB (Committee for Health-Related Evaluation of Building Products) scheme and on the French regulations for labeling building products. To summarize, it may be stated in conclusion that although the products tested do represent a source of emissions in the indoor environment the level of such emissions is however comparatively low.
;
Im Rahmen eines Forschungsprojekts wurden erstmals Türblätter und Türzargen nach DIN EN 14351-2 mit der Prüfkammermethode umfassend auf raumluftrelevante Emissionen untersucht. Die Untersuchungen erfolgten sowohl in 1-m³-Prüfkammern wie auch in einer begehbaren 24-m³-Prüfkammer. Die raumlufthygienische Bewertung der Ergebnisse basiert auf dem deutschen AgBB-Schema und der französischen Verordnung zur Kennzeichnung von Bauprodukten. Zusammenfassend kann festgestellt werden, dass die untersuchten Produkte zwar eine Quelle für Emissionen im Innenraum darstellen, die Höhe der Emissionen aber vergleichsweise gering ist.