A novel, hydroxyapatite-based screw-like device for anterior cruciate ligament (ACL) reconstructions

Abstract
Background: Rupture of the anterior cruciate ligament (ACL) is one of the most common injuries of the knee. Common techniques for ACL reconstruction require a graft fixation using interference screws. Nowadays, these interference screws are normally made of titanium or polymer/ceramic composites. The main challenge of application of a fixation device made entirely of bioactive ceramic is in relation to the low strength of such materials. The purpose of this study was to evaluate a novel geometry for a fixation device made of pure hydroxyapatite for ACL reconstructions that can overcome some problems of the titanium and the polymer/ceramic screws. Methods: Finite Element Analysis was used for optimization of the stress distribution in conventional interference screw geometry. For experimental evaluation of the new fixation device, ex vivo tests were performed. Results: The innovative screw-like fixation device is characterized by multiple threads with a large thread pitch. The novel design enabled the insertion of the screw into the bone without the application of an external torque or a screwdriver. In turn, it also allowed for the use of low-strength and high-bioactivity materials, like hydroxyapatite. Ex vivo tests showed that the novel screw can sustain pull-out forces up to 476 N, which is comparable to that of the commercially available BioCompositeTM interference screws (Arthrex Inc., Germany), as a reference. Conclusions: In summary, the novel screw design is a promising strategy to develop all-ceramic fixation devices for ACL reconstructions, which may eliminate some drawbacks of the current interference screws.
Author(s)
Schumacher, Thomas C.
Advanced Ceramics, University of Bremen, 28359 Bremen, Germany
Tushtev, Kamen
Advanced Ceramics, University of Bremen, 28359 Bremen, Germany
Wagner, Ulrich
AMEOS Klinikum Seepark Geestland, 27607 Geestland, Germany & University of Bonn, 53113 Bonn, Germany
Becker, Caroline
AMEOS Klinikum Seepark Geestland, 27607 Geestland, Germany & University of Bonn, 53113 Bonn, Germany
Große Holthaus, Marzellus
BEGO Implant Systems GmbH & Co. KG, 28359 Bremen, Germany
Hein, Sebastian B.
Fraunhofer-Institut für Fertigungstechnik und Angewandte Materialforschung IFAM  
Haack, Janne  
Fraunhofer-Institut für Fertigungstechnik und Angewandte Materialforschung IFAM  
Heiss, Christian
Laboratory of Experimental Trauma Surgery, Justus-Liebig-University of Giessen, 35394 Gießen, Germany
Engelhardt, Markus
Laboratory of Experimental Trauma Surgery, Justus-Liebig-University of Giessen, 35394 Gießen, Germany
Khassawna, Thaqif el
Laboratory of Experimental Trauma Surgery, Justus-Liebig-University of Giessen, 35394 Gießen, Germany
Rezwan, Kurosch
Advanced Ceramics, University of Bremen, 28359 Bremen, Germany & MAPEX Centre for Materials and Processes, University of Bremen, 28359 Bremen, Germany
Journal
The knee  
Funder
Bundesministerium für Bildung und Forschung BMBF (Deutschland)  
Open Access
DOI
10.1016/j.knee.2017.07.005