• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Artikel
  4. Improved closed test setup for biodegradation testing of slightly volatile substances in water-sediment systems (OECD 308)
 
  • Details
  • Full
Options
March 4, 2023
Journal Article
Title

Improved closed test setup for biodegradation testing of slightly volatile substances in water-sediment systems (OECD 308)

Abstract
Standardized biodegradation testing methods, like the OECD 308 Aerobic and Anaerobic Transformation in Aquatic Sediment Systems, generate data on biodegradation required during environmental risk and hazard assessment of chemicals under different European and international regulations. However, difficulties arise when applying the OECD 308 guideline for testing hydrophobic volatile chemicals. Especially the use of a co-solvent (like acetone) as a measure to facilitate the application of the test chemical in combination with a closed setup to reduce losses due to volatilization tend to deplete/restrict the amount of oxygen in the test system. The result is a low oxygen or even anoxic water column in the water-sediment system. Thus, the degradation half-lives of the chemical generated from such tests are not directly comparable to the regulatory half-life values for Persistence assessment of the test chemical. The aim of this work was to further develop the closed setup to improve and maintain aerobic conditions in the water phase of the water-sediment systems for testing slightly volatile hydrophobic test chemicals. This improvement was attained by optimizing the test system geometry and agitation technique to maintain aerobic conditions in the water phase in a closed test setup, investigating appropriate co solvent application strategy, and trialing the resulting test setup. This study shows that when using a closed test setup for OECD 308 tests, agitation of the water phase overlaying the sediment and the test item application using low co-solvent volume is critical for maintaining an aerobic water layer.
Author(s)
Shrestha, Prasit  
Fraunhofer-Institut für Molekularbiologie und Angewandte Oekologie IME  
Hughes, Christopher B.
Camenzuli, Louise
Lyon, Delina
Meisterjahn, Boris  
Fraunhofer-Institut für Molekularbiologie und Angewandte Oekologie IME  
Hennecke, Thomas
Fraunhofer-Institut für Molekularbiologie und Angewandte Oekologie IME  
Griffiths, Megan
Hennecke, Dieter  
Fraunhofer-Institut für Molekularbiologie und Angewandte Oekologie IME  
Journal
Chemosphere  
Open Access
DOI
10.1016/j.chemosphere.2023.138294
Language
English
Fraunhofer-Institut für Molekularbiologie und Angewandte Oekologie IME  
Fraunhofer Group
Fraunhofer-Verbund Ressourcentechnologien und Bioökonomie  
Keyword(s)
  • Biodegradation

  • Volatile chemicals

  • OECD 308

  • Improved test setup

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024