• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Konferenzschrift
  4. Cantilever micro balance as nanoparticle exposure monitor
 
  • Details
  • Full
Options
2014
Conference Paper
Title

Cantilever micro balance as nanoparticle exposure monitor

Abstract
An electrophoretic cantilever-based nanoparticle (NP) sensor was described for personal monitoring of occupational exposure at workplace. Online measurements performed under defined NP concentrations in a climate chamber confirmed the feasibility of the measurement principle. Cyclic switching between NP sampling and frequency tracking revealed settling times of 5 min and 1.5 min,respectively, until stable conditions were reached. Using an improved design of the sampling head a fully integrated pocket-size system offers a reduced response time of 20 s.
Author(s)
Wasisto, H.S.
Waag, A.
Merzsch, S.
Uhde, E.
Peiner, E.
Mainwork
MME 2014, 25th Micromechanics and Microsystems Europe Workshop. CD-ROM  
Conference
Micromechanics and Microsystems Europe Workshop (MME) 2014  
Language
English
Fraunhofer-Institut für Holzforschung Wilhelm-Klauditz-Institut WKI  
Keyword(s)
  • engineered airborne nanoparticles

  • cantilever resonator

  • electrophoretic sampler

  • personal monitor

  • direct read out

  • pocket size system