Title

Functionalization of screw implants with superelastic structured Nitinol anchoring elements

Abstract
Background: Demographic change is leading to an increase in the number of osteoporotic patients, so a rethink is required in implantology in order to be able to guarantee adequate anchoring stability in the bone. The functional modification of conventional standard screw implants using superelastic, structured Ti6Al4V anchoring elements promises great potential for increasing anchoring stability. Methods: For this purpose, conventional screw implants were mechanically machined and extended so that structured-superelastic-positionable-Ti6Al4V anchoring elements could be used. The novel implants were investigated with three tests. The setup of the anchoring elements was investigated in CT studies in an artificial bone. In a subsequent simplified handling test, the handling of the functional samples was evaluated under surgical conditions. The anchorage stability compared to standard screw implants was investigated in a final pullout test according to ASTM F543âthe inter national for the standard specification and test methods for metallic medical bone screws. Results: The functionalization of conventional screw implants with structured superelastic Ti6Al4V anchoring elements is technically realizable. It was demonstrated that the anchoring elements can be set up in the artificial bone without any problems. The anchorage mechanism is easy to handle under operating conditions. The first simplified handling test showed that at the current point of the investigations, the anchoring elements have no negative influence on the surgical procedure (especially under the focus of screw implantation). Compared to conventional standard screws, more mechanical work is required to remove the functional patterns completely from the bone. Conclusion: In summary, it was shown that conventional standard screw implants can be functionalized with Ti6Al4V-structured NiTi anchoring elements and the new type of screws are suitable for orthopedic and neurosurgical use.
Author(s)
Hamann, I.
Schleifenbaum, S.
Rotsch, C.
Drossel, W.-G.
Heyde, C.-E.
Leimert, M.
Journal
BioMedical Engineering OnLine  
Open Access
DOI
10.1186/s12938-021-00975-4
Additional link
Full text
Language
English
Fraunhofer-Institut für Werkzeugmaschinen und Umformtechnik IWU  
  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024