• English
  • Deutsch
  • Log In
    Password Login
    Research Outputs
    Fundings & Projects
    Researchers
    Institutes
    Statistics
Repository logo
Fraunhofer-Gesellschaft
  1. Home
  2. Fraunhofer-Gesellschaft
  3. Artikel
  4. Comparison of a Quantum Cascade Laser and an Interband Cascade Laser for the Detection of Stable Carbon Dioxide Isotopes Using Tunable Laser Absorption Spectroscopy
 
  • Details
  • Full
Options
2025
Journal Article
Title

Comparison of a Quantum Cascade Laser and an Interband Cascade Laser for the Detection of Stable Carbon Dioxide Isotopes Using Tunable Laser Absorption Spectroscopy

Abstract
Quantum cascade lasers (QCLs) and interband cascade lasers (ICLs) are widely used as light sources in tunable laser absorption spectroscopy because they emit in the mid-infrared region where many strong and characteristic absorption bands are present. In this paper, we compare the performance of these lasers emitting at about 2310.1 cm-1 to determine an optimal light source for detecting isotopic ratios of carbon dioxide (CO2). Our results show that the QCL has a higher relative intensity noise of up to 15 dBc/Hz compared to the ICL over the entire measured frequency range. In addition, it has a higher frequency fluctuation. However, the maximum tuning range of the QCL is up to 5.2 cm-1 compared to up to 3.8 cm-1 for the ICL. Both lasers lose more than half of their tuning range when the tuning rate is increased to 10 kHz. When measuring the isotope ratio of CO2, an uncertainty in the (Formula presented.) value of (Formula presented.) ‰ was achieved with the ICL and of (Formula presented.) ‰ with the QCL, both at an integration time of 0.2 s. In summary, the QCL is more appropriate for applications that require a larger spectral tuning range, such as the measurement of a complex gas mixture, while the ICL has an excellent signal-to-noise ratio and is therefore better suited for applications that require higher precision.
Author(s)
Nitzsche, Ponkanok
Univ. Freiburg/Brsg., Institut für Mikrosystemtechnik -IMTEK-  
Dinc, Cem
Univ. Freiburg/Brsg., Institut für Mikrosystemtechnik -IMTEK-  
Goldschmidt, Jens
Univ. Freiburg/Brsg., Institut für Mikrosystemtechnik -IMTEK-  
Nitzsche, Leonard
Univ. Freiburg/Brsg., Institut für Mikrosystemtechnik -IMTEK-  
Wöllenstein, Jürgen  
Fraunhofer-Institut für Physikalische Messtechnik IPM  
Schmitt, Katrin  
Fraunhofer-Institut für Physikalische Messtechnik IPM  
Journal
Applied spectroscopy  
DOI
10.1177/00037028241291157
Language
English
Fraunhofer-Institut für Physikalische Messtechnik IPM  
Keyword(s)
  • Quantum cascade laser

  • Interband cascade laser

  • Tunable laser absorption spectrometry

  • Stable carbon dioxide isotope detection

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024