Validation of Thermocline Storage Model with Experimental Data of a Laboratory-Scale Molten Salt Test Facility

Abstract
The Fraunhofer ISE single-tank simulation model was parameterized and inputs were set according to the Fraunhofer ISE lab-scale storage tank in order to validate the model. The measured stratification during the charging cycle was compared to the temperature distribution of the simulated storage tank. If the effective diffusivity factor was calculated according to literature correlations, it corresponded very well with the measurement data with a mean standard deviation of 1.21%. A parameter identification for the effective diffusivity factor of the storage was performed to reduce these deviations even further. It showed that the ideal effective diffusivity factor is 150. The mean standard deviation was further reduced to 1.14 %.
Author(s)
Zoschke, T.
Karl, M.
Fluri, T.
Müller, R.
Hauptwerk
SolarPACES 2018, 24th International Conference on Concentrating Solar Power and Chemical Energy Systems
Konferenz
International Conference on Concentrating Solar Power and Chemical Energy Systems (SolarPACES) 2018
DOI
10.1063/1.5117749
File(s)
N-565210.pdf (454.44 KB)
Language
English
google-scholar
Fraunhofer-Institut für Solare Energiesysteme ISE
Tags
  • Thermische Systeme und Gebäudetechnik

  • Solarthermie

  • Thermische Speicher für Kraftwerke und Industrie