Validation of Thermocline Storage Model with Experimental Data of a Laboratory-Scale Molten Salt Test Facility

Abstract
The Fraunhofer ISE single-tank simulation model was parameterized and inputs were set according to the Fraunhofer ISE lab-scale storage tank in order to validate the model. The measured stratification during the charging cycle was compared to the temperature distribution of the simulated storage tank. If the effective diffusivity factor was calculated according to literature correlations, it corresponded very well with the measurement data with a mean standard deviation of 1.21%. A parameter identification for the effective diffusivity factor of the storage was performed to reduce these deviations even further. It showed that the ideal effective diffusivity factor is 150. The mean standard deviation was further reduced to 1.14 %.
Author(s)
Zoschke, Theda  
Karl, Martin
Fluri, Thomas  
Müller, Ralf
Mainwork
SolarPACES 2018, 24th International Conference on Concentrating Solar Power and Chemical Energy Systems  
Conference
International Conference on Concentrating Solar Power and Chemical Energy Systems (SolarPACES) 2018  
File(s)
Download (454.44 KB)
Rights
Use according to copyright law
DOI
10.1063/1.5117749
10.24406/publica-r-405623
Additional link
Full text
Language
English
Fraunhofer-Institut für Solare Energiesysteme ISE  
Keyword(s)
  • Thermische Systeme und Gebäudetechnik

  • Solarthermie

  • Thermische Speicher für Kraftwerke und Industrie