  4. Portable Impedance Analyzer for FET-Based Biosensors with Embedded Analysis of Randles Circuits’ Spectra
 
  • Details
  • Full
Options
2025
Journal Article
Title

Portable Impedance Analyzer for FET-Based Biosensors with Embedded Analysis of Randles Circuits’ Spectra

Abstract
The electrochemical impedance spectroscopy (EIS) is a measurement method for characterizing bio-recognition events of a sensor, such as field-effect transistor-based biosensors (BioFETs). Due to the lack of portable impedance spectroscopes, EIS applies mainly in laboratories preventing application-oriented use in the field. This work presents a portable impedance analyzer (PIA) providing a 4-channel EIS of BioFETs. It performs the analysis of the recorded spectra by determining the charge transfer resistance (Formula presented.) with a power-saving algorithm. Therefore, a circle is fitted into the Nyquist representation of the Randles circuit, from whose zero crossings (Formula presented.) can be determined. The introduced algorithm was evaluated on 100 simulated spectra of Randles circuits. To analyze the overall system, an adjustable reference circuit was developed that simulates configurable Randles circuits. Additional measurements with pH-sensitive ion-sensitive field-effect transistors (ISFETs) demonstrate the application of the measurement system with electrochemical sensors. Using simulated spectra, the circular fitting is able to detect (Formula presented.) with a median accuracy of (Formula presented.) at an average nominal power of 40 mW and 3054 µs computing time. The PIA with the embedded implementation of the circuit fitting achieves a median error for R<inf>ct</inf> of 4.2% using the introduced Randles circuit simulator (RCS). Measurements with ISFETs show deviations of 6.5 ± 2.8% compared to the complex non-linear least squares (CNLS), but is significantly faster and more efficient. The presented system allows a portable, power-saving performance of EIS. Future optimizations for a specific applications can improve the presented system and enable novel low-power and automated measurements of biosensors outside the laboratory.
Author(s)
Pfeiffer, Norman  
Fraunhofer-Institut für Integrierte Schaltungen IIS  
Bach, Martin  
Fraunhofer-Institut für Integrierte Schaltungen IIS  
Steiner, Alice
Fraunhofer-Institut für Integrierte Schaltungen IIS  
Gerhardt, Anna Elisabeth
Fraunhofer-Institut für Integrierte Schaltungen IIS  
Bausells, Joan
CSIC - Instituto de Microelectronica de Barcelona (IMB-CNM)
Errachid, Abdelhamid
Institut des Sciences Analytiques
Heuberger, Albert  
Fraunhofer-Institut für Integrierte Schaltungen IIS  
Journal
Sensors
Funder
Bundesministerium für Bildung und Forschung  
Open Access
DOI
10.3390/s25113497
Additional link
Full text
Language
English
Fraunhofer-Institut für Integrierte Schaltungen IIS  
Keyword(s)
  • circular fitting

  • electrochemical impedance spectroscopy

  • FET-based biosensors

  • impedance analyzer

  • ISFET

  • randles circuit