Cost-optimal inverter sizing for ancillary services - field experience in Germany and future considerations

Abstract
This paper shows how an additional provision of reactive power influences the economically optimized sizing of inverters for photovoltaic systems in Germany. At first, the results of an encompassing survey among 934 photovoltaic system operators show the current inverter sizing experiences for a region in South-East Bavaria. In a second step an analytical approach for the determination of the economically optimized inverter sizing is introduced, considering active as well as reactive power provision. The simulation results, shown in this paper, are based on real DC measurement data of modules at a test site in Germany, with a time resolution of 1 minute for a period of four years. It is shown that an additional reactive power provision leads to higher economically optimized inverter sizing compared to pure active power feed-in, depending on the actual reactive power supply method and the minimum power factor required.
Author(s)
Stetz, T.
Appen, J. von
Braun, M.
Wirth, G.
Mainwork
26th European Photovoltaic Solar Energy Conference and Exhibition, EU PVSEC. Proceedings  
Conference
European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC) 2011  
File(s)
Download (385.74 KB)
DOI
10.24406/publica-r-392942
10.4229/26thEUPVSEC2011-4DP.2.2