Options
2025
Conference Paper
Title
Active ultrasonic measurements for machine condition monitoring
Abstract
The paper examines the use of active ultrasonic measurements to determine the state of machines. The measurement system consists of a lateral capacitive micromachined ultrasonic transmitter, a wideband MEMS microphone and an accelerometer. The ultrasound is reflected by a device under test. If the device is not active, the soundwaves will be in a steady state. When the device is active and vibrates, the reflected ultrasonic echo will be a superposition of the transmitted frequency and the vibration of the device. The signals are evaluated in time and frequency domain using statistics. Additionally, machine learning is used to train a classifier to detect different states of the vibration. The capabilities of the three sensors are compared in a controlled experiment on a vibration stage, where the frequency and acceleration of the vibration is defined. The sensor node is then used to classify the state of a saw blade on a miter saw. The active ultrasonic measurements add additional information to the machine learning models, which increases the accuracy of the predictions.
Mainwork
Conference Record IEEE Instrumentation and Measurement Technology Conference
Conference
2025 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2025