Improvements to a method for determining leg length following total hip arthroplasty

Abstract
Discrepancy in leg length does frequently occur as a side effect of total hip arthroplasty and may lead to reduced patient satisfaction as well as injury in the sequalae. It is consequently important to reduce leg length discrepancy where-ever technically possible. This may be achieved by recording precise intraoperative measurements and using different sized implanted components. The aim of the given study was to improve the accuracy of a previously validated optic measurement system (OMS) to reduce leg length discrepancy. This pre-existing OMS was first trialled and based on these preliminary findings developed further. Using this improved system, measurements were taken in models and cadavers. Inter observer reliability of the improved OMS was assessed. The system is introduced in the given technical feasibility study. Its accuracy was greater in the model setup (swivel joint: 772.7 ± 1.5 mm; ball joint: 770.0 ± 3.7 mm; reference: 772 mm) compared to the trial using cadaveric tissues (588.8 ± 5.7 mm; reference: 586 mm). Results of two examiners were similar. The third one measured significantly shorter values (p=.011). The results of the measurements with the OMS indicate that a significant increase in accuracy (p = 2.076×10−6) has been achieved compared to the previously reported system, however, a further improvement to measurement accuracy is necessary for this to be applied clinically.
Author(s)
Wendler, Toni
Universität Leipzig
Heilemann, Martin
Universität Leipzig
Grunert, Ronny  
Fraunhofer-Institut für Werkzeugmaschinen und Umformtechnik IWU  
Möbius, Robert
Universität Leipzig
Schmidt, Michael
Universität Leipzig
Schleifenbaum, Stefan
Universität Leipzig
Prietzel, Torsten
Zeisigwaldkliniken Bethanien Chemnitz
Journal
Journal of Medical Engineering and Technology  
DOI
10.1080/03091902.2020.1723727
Language
English
Fraunhofer-Institut für Werkzeugmaschinen und Umformtechnik IWU  
Keyword(s)
  • leg length determination

  • intraoperative measurements

  • total hip arthroplasty

  • Optical Measuring System

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Contact
© 2024