Detection limits of contamination analysis by nitrogen RBS

Abstract
Rutherford Backscattering Spectroscopy using a primary beam of Nitrogen Ions is a powerful tool to measure trace elements on surfaces. A detection limit of 10 high 10 At/square centimetre for heavy elements (gold) and 10 high 12 At/square centimetre medium elements (As) is reached.
Author(s)
Weidhaas, J.
Lang, W.
Conference
Quantitative Surface Analysis 1990  
Language
English
IFT  
Keyword(s)
  • Rutherford scattering

  • surface analysis

  • trace element