Richter, F.F.RichterEberle, J.J.EberleHolz, R.R.HolzNeff, W.W.NeffLebert, R.R.Lebert2022-03-082022-03-081989https://publica.fraunhofer.de/handle/publica/316856The radiation characteristics of a plasma focus operated with nitrogen is investigated. To optimize this source at a particular wavelength with respect to its application in X-ray microscopy, several diagnostic methods are applied to measure the emitted radiation with temporal, spectral and spatial resolution. A well suited diagnostic technique is the imaging of the source by means of a condenser zone plate.enbiologisches Laborbiology-laboratoryCharakteristika StrahlungLochkameramonochromatic imagingmonochromatische Abbildungnitrogenpinhole cameraradiation characteristicRöntgenstrahlenbildmikroskopwavelength regionWellenlängex-ray imaging microscopy621A source for soft x-ray imaging microscopy with nanosecond exposure time.Quelle für eine Röntgen-Bildmikroskopie mit einer Belichtungszeit im Bereich von Nanosekundenconference paper