Hattenhorst, B.B.HattenhorstBaer, C.C.BaerMusch, T.T.MuschJaeschke, T.T.JaeschkePohl, N.N.Pohl2022-03-052022-03-052016https://publica.fraunhofer.de/handle/publica/25486210.1515/freq-2016-0216In this contribution, a composite measurement concept for the gas flow determination in diverse stream scenarios is presented. The approach utilizes the pressure- and mixing-dependent relative permittivity of gaseous media, which, in case of a vortex or a marker gas, creates a detectable variation in the measuring beam of the radar. Since the measurement effect is very small, phase measurements based on highly precise and low jitter frequency-modulated continuous-wave radar systems in different frequency bands are applied. Moreover, disturbances caused by vibrations of the measurement setup are compensated out of the measurement signal.en621Gas Flow Monitoring in High and Low Reynolds Regimes Based on Compensated FMCW-Radar Phase Measurementsjournal article