Status of the undulator system of the seeded HGHG-FEL test bench at MAX-lab

Titel Supplements
Presentation held at the International Free Electron Laser Conference 2007, Novosibirsk
Abstract
Within the EUROFEL Design Study a seeded HGHG-FEL will be set up at the 450 MeV linac at MAX-lab. The undulators and the dispersive section have been installed. Two different glass fiber based radiation dose monitors have been integrated. We report on the performance of these components. The impact of electron losses on undulator magnets and the Cherenkov fibers have been simulated. The THz radiation as produced by the bunched electron beam in the dump magnet can be used as a measure of the longitudinal and transverse overlap of the electron beam and the laser beam which has been concluded from simulations.
Author(s)
Bahrdt, J.
BESSY, Berlin
Frentrup, W.
BESSY, Berlin
Gaupp, A.
BESSY, Berlin
Goldammer, K.
BESSY, Berlin
Holldack, K.
BESSY, Berlin
Scheer, M.
BESSY, Berlin
Brandin, M.
Lund University, Lund
Lindau, F.
Lund University, Lund
Pugachov, D.
Lund University, Lund
Thorin, S.
Lund University, Lund
Werin, S.
Lund University, Lund
Kuhnhenn, J.
Fraunhofer-Institut für Naturwissenschaftlich-Technische Trendanalysen INT
Konferenz
International Free Electron Laser Conference (FEL) 2007
DOI
10.24406/publica-fhg-355394
File(s)
001.pdf (1.03 MB)
Language
English
google-scholar
Fraunhofer-Institut für Naturwissenschaftlich-Technische Trendanalysen INT
Tags
  • fiber optic radiation...

  • Cherenkov detector

  • undulator

  • Cookie settings
  • Imprint
  • Privacy policy
  • Api
  • Send Feedback
© 2022