Options
1995
Conference Paper
Titel
Computerlaminografie unter Verwendung eines Transmissionsstargets
Abstract
In computed laminography object cross sections are reconsturcted form digital profections taken during the obfect motion. By this new laminographic method the detector and the X-ray source remain fixed, only the object is moved in a translation across the fan beam of the microfocal X-ray source. The axial resolution depends on the opening angle of the fan beam. The paper shows the improvement of the resolution by using a transmission target in the microfocal X-ray source103. This allows the measurement of the projections in a fan beam with an opening of more than 90 ø. The artifacts in the axial directions are considerably reduced. The method is applied to the investigation of electronic boards and of welds.