Fraunhofer-Gesellschaft

Publica

Hier finden Sie wissenschaftliche Publikationen aus den Fraunhofer-Instituten.

Stabilization of high-deposition-rate reactive magnetron sputtering of oxides by in situ spectroscopic ellipsometry and plasma diagnostics

 
: Vergöhl, M.; Hunsche, B.; Malkomes, N.; Matthee, T.; Szyszka, B.

:

Journal of vacuum science and technology A. Vacuum, surfaces and films 18 (2000), Nr.4, S.1709-1712
ISSN: 0734-2101
American Vacuum Society (National Symposium) <46, 1999, Seattle/Wash.>
Englisch
Zeitschriftenaufsatz, Konferenzbeitrag
Fraunhofer IST ()

Abstract
A control system for stabilizing the reactive magnetron-sputter process is applied that is based on a combination of a short-term stabilization of the plasma and a long-term stabilization employing an in situ spectroscopic ellipsometer. For the formation of niobium pentoxide, a measurement of the reactive gas partial pressure with a lambda -probe measurement was employed. It turns out that the specific deposition rate, i.e., deposition rate divided by the power density, is a suitable control parameter. Compared to the oxide mode, the deposition rate of niobium pentoxide films deposited in the transition mode could be enlarged by a factor of more than 4. The films were grown at different process parameters (oxygen partial pressure, target power, absolute pressure, midfrequency and dc technique) onto unheated substrates. In situ spectroscopic ellipsometry and ex situ spectroscopic ellipsometry at different angles of incidence and scanning electron microscopy investigations were applied to study the optical properties and the morphology of the films.

: http://publica.fraunhofer.de/dokumente/N-3816.html