Fraunhofer-Gesellschaft

Publica

Hier finden Sie wissenschaftliche Publikationen aus den Fraunhofer-Instituten.

Symmetry-based detection and diagnosis of DCIS in breast MRI

 
: Srikantha, A.; Harz, M.T.; Newstead, G.; Wang, L.; Platel, B.; Hegenscheid, K.; Mann, R.M.; Hahn, H.K.; Peitgen, H.-O.

:

Novak, C.L. ; Society of Photo-Optical Instrumentation Engineers -SPIE-, Bellingham/Wash.:
Medical Imaging 2013. Computer-Aided Diagnosis. Vol.1 : 12 - 14 February 2013, Lake Buena Vista, Florida, United States
Bellingham, WA: SPIE, 2013 (Proceedings of SPIE 8670)
ISBN: 978-0-8194-9444-3
ISSN: 1605-7422
Paper 86701E
Conference "Medical Imaging - Computer-Aided Diagnosis" <2013, Lake Buena Vista/Fla.>
Englisch
Konferenzbeitrag
Fraunhofer MEVIS ()

Abstract
The delineation and diagnosis of non-mass-like lesions, most notably DCIS (ductal carcinoma in situ), is among the most challenging tasks in breast MRI reading. Even for human observers, DCIS is not always easy to diferentiate from patterns of active parenchymal enhancement or from benign alterations of breast tissue. In this light, it is no surprise that CADe/CADx approaches often completely fail to classify DCIS. Of the several approaches that have tried to devise such computer aid, none achieve performances similar to mass detection and classification in terms of sensitivity and specificity. In our contribution, we show a novel approach to combine a newly proposed metric of anatomical breast symmetry calculated on subtraction images of dynamic contrast-enhanced (DCE) breast MRI, descriptive kinetic parameters, and lesion candidate morphology to achieve performances comparable to computer-aided methods used for masses. We have based the development of the method on DCE MRI data of 18 DCIS cases with hand-annotated lesions, complemented by DCE-MRI data of nine normal cases. We propose a novel metric to quantify the symmetry of contralateral breasts and derive a strong indicator for potentially malignant changes from this metric. Also, we propose a novel metric for the orientation of a finding towards a fix point (the nipple). Our combined scheme then achieves a sensitivity of 89% with a specificity of 78%, matching CAD results for breast MRI on masses. The processing pipeline is intended to run on a CAD server, hence we designed all processing to be automated and free of per-case parameters. We expect that the detection results of our proposed non-mass aimed algorithm will complement other CAD algorithms, or ideally be joined with them in a voting scheme.

: http://publica.fraunhofer.de/dokumente/N-241466.html